Ford Mustang (1999-2004) Service Manual: Evaporative Emission Repair Verification Drive Cycle

Special Tool(s)

Worldwide Diagnostic System (WDS) 418-F224, New Generation STAR (NGS) Tester 418-F052, or equivalent scan tool

Drive Cycle Recommendations

NOTE: The following procedure is designed to execute and complete the evaporative emission repair verification drive cycle and to clear the Ford P1000, inspection and maintenance (I/M) readiness code.

When the ambient air temperature is below 4.4C (40F) or above 37.8C (100F), or the altitude is above 2,438 meters (8,000 feet), the EVAP monitor will not run. If the P1000 must be cleared in these conditions, the powertrain control module (PCM) must detect them once (twice on some applications) before the EVAP monitor can be bypassed and the P1000 cleared. The EVAP bypassing procedure is described in the following drive cycle.

1. Most OBD II monitors will complete more readily using a steady foot driving style during cruise or acceleration modes. Operating the throttle in a smooth fashion will minimize the time necessary for monitor completion.

2. Fuel tank level should be between one-half and three-quarters full with three-quarters full being the most desirable.

3. The evaporative monitor can only operate during the first 30 minutes of engine operation. When executing the procedure for this monitor, stay in part throttle mode and drive in a smooth fashion to minimize fuel slosh.

Drive Cycle Preparation

NOTE: For best results, follow each of the following steps as accurately as possible.

4. NOTE: This step bypasses the engine soak timer and resets OBD II monitor status.

Install the scan tool. Turn the key ON with the engine OFF. Cycle the key off, then on. Select the appropriate vehicle and engine qualifier. Clear all diagnostic trouble codes (DTCs) and carry out a PCM reset.

5. Begin to monitor the following PIDs: ECT, EVAPDC, FLI (if available) and TP MODE. Press Diagnostic Data Link, PCM, PID/Data monitor and record, press trigger to select each PID, then start.

6. Start the engine without returning the key to the OFF position.

Preparation for Monitor Entry

WARNING: Strict observance of posted speed limits and attention to driving conditions are mandatory when proceeding through the following drive cycle.

7. NOTE: This step allows engine warm-up and provides intake air temperature (IAT) input to the PCM.

Idle the vehicle for 15 seconds. Drive at 64 km/h (40 mph) until the ECT is at least 76.7C (170 F).

8. Is IAT above 4.4C (40F) and below 37.8C (100F)? If not, continue with the following steps but note that the EVAP Monitor Bypass portion of the drive cycle (Step 13) will be required to bypass the EVAP monitor and clear the P1000.

9. NOTE: This step executes the heated oxygen sensor (HO2S) monitor.

Cruise at 64 km/h (40 mph) for 60 seconds.

10. NOTE: This executes the EVAP monitor if IAT is above 4.4C (40F) and below 37.8C (100F).

NOTE: To initiate the monitor, TP MODE should equal PT, EVAPDC must be greater than 75%, and FLI must be between 15 and 85%.

NOTE: Avoid sharp turns and hills.

Cruise at 72 to 104 km/h (45 to 65 mph) for 10 minutes.

11. NOTE: This step executes the ISC portion of the Secondary Air/CCM.

Bring the vehicle to a stop. Idle with the transmission in DRIVE (for automatic transmission) or NEUTRAL (for manual transmission) for two minutes.

Pending Code and EVAP Monitor Bypass Check

12. NOTE: This determines if a pending code is preventing the clearing of P1000.

NOTE: If the EVAP monitor is not complete and IAT was below 4.4C (40F) or above 37.8C (100F) temperature range in Step 8, or the altitude is above 2,438 meters (8,000 feet), the EVAP Monitor Bypass (Step 13) must be carried out.

Using the scan tool, check for pending codes. Conduct normal repair procedures for any pending code concerns. Rerun any incomplete monitor.

EVAP Monitor Bypass

13. NOTE: This allows the bypass counter to increment to two.

NOTE: Do not repeat Step 4.

Park the vehicle for a minimum of eight hours. Repeat Steps 5 through 12.

    Evaporative Emission System Leak Test
    Special Tool(s) Evaporative Emission System Tester 310-F007 (134-00056) or equivalent Worldwide Diagnostic System (WDS) 418-F224, New Generation STAR (NGS) Tester ...

    Evaporative Emission Canister
    Removal and Installation 1. WARNING: The evaporative emission system contains fuel vapor and condensed fuel vapor. Although not in large quantities, it still presents the danger of explosion ...

    Other materials:

    Using MyKey with remote start systems
    MyKey is not compatible with non-Ford-approved aftermarket remote start systems. If you choose to install a remote start system, please see your Ford authorized dealer for a Ford-approved remote start system. Vehicles With Ford-approved Aftermarket Remote Sta ...

    Multifunction Electronic Control Modules
    Torque Specifications Module Controlled Functions The generic electronic module (GEM)(14B205) is the only multifunction control module on this vehicle. The GEM controls the following functions: warning chimes and warning lamps one-touch down ...

    Purging - CIII Power Steering Pump
    Special Tool(s) Vacuum Pump 416-D002 (D95L-7559-A) or Equivalent CAUTION: If the air is not purged from the power steering system correctly, premature power steering pump failure can result. This condition can occur on pre-delivery vehicles ...