Ford Mustang (1999-2004) Service Manual: Hydraulic Control Unit

Removal

1. Disconnect the battery ground cable(14301).

2. Disconnect the anti-lock-brake control module electrical connector.

Hydraulic Control Unit

3. NOTE: The 4 wheel anti-lock brake system (4WABS) with traction control is shown , the 4WABS without traction control system is similar with one less hydraulic line.

NOTE: Plug brake lines to prevent any brake fluid loss.

Disconnect the brake lines from the hydraulic control unit (HCU).

Hydraulic Control Unit

4. Remove the HCU bracket nuts to HCU.

Hydraulic Control Unit

5. Remove the HCU.

Hydraulic Control Unit

6. Remove the pump motor electrical connector.

Hydraulic Control Unit

7. Remove the anti-lock-brake control module screws.

Hydraulic Control Unit

8. Remove the anti-lock-brake control module from the HCU.

Installation

1. NOTE: The brake system must be bled after the HCU is installed or replaced. To install, reverse the removal procedure.

Hydraulic Control Unit

 

Hydraulic Control Unit

    Sensor Indicator - Rear
    Special Tool(s) Pinion Bearing Cone Remover 205-D002 (D79P-4621A) Axle Bearing/Seal Plate 205-090 (T75L-1165-B) Sensing Ring Replacer 206-041 (T89P-20202-A) Removal ...

    Module
    Removal 1. Remove the hydraulic control unit (HCU). Refer to Hydraulic Control Unit . 2. Remove the pump motor electrical connector. 3. Remove the anti-lock-brake control module screws. 4. Remove th ...

    Other materials:

    Lighting control
    A. Off B. Parking lamps, instrument panel lamps, license plate lamps and tail lamps C. Headlamps High Beams • Push the lever toward the instrument panel to switch on the high beams. • Pull the lever toward you to switch of the high beams. Headlamp Flashe ...

    Engine (Removal)
    Special Tool(s) Special Tool(s) Support Bracket, Engine 303-639 Spreader Bar 303-D089 (D93P-6001-A3) Lifting Bracket Set, Engine 303-D074 (D91P-6001-A) Removal 1. Remove the hood. 2. Remove the battery. For additi ...

    Installation
    All vehicles 1. NOTE: If the valve cover is not secured within four minutes, the sealant must be removed and the sealing area cleaned with metal surface cleaner. Allow to dry until there is no sign of wetness, or four minutes, whichever is longer. Failure to ...