Ford Mustang (1999-2004) Service Manual: Blower Motor
Removal
1. Disconnect the jumper wire.

2. Disconnect the main harness.

3. Remove the screws.

4. Separate the cover from the motor.

5. Separate the motor from the housing.

6. Disconnect the jumper from the motor.
- Remove the blower motor.

Installation
1. To install, reverse the removal procedure.
Heating and Defrosting
The heating and defrosting system has the following features:
Controls the temperature and, during A/C operation, reduces the relative
humidity of the air
inside the vehicle.
Delivers heated or ...
Evaporator Core Housing
Material
Item
Specification
PAG Compressor Oil (R-134a
Systems)
F7AZ-19589-DA (Motorcraft
YN-12-C)
WSH-M1C231-
B
MERPOL
NA
ESE-M99B144-
B
Removal
NOTE: The evapor ...
Other materials:
Temperature and Manifold Absolute Pressure (T-MAP)
Sensor - Cobra
Removal and Installation
1. Disconnect the temperature manifold absolute pressure (T-MAP)
sensor electrical connector.
2. Remove the bolts and the T-MAP sensor.
3. To install, reverse the removal procedure. ...
Body Sealer Types And Applications
Liquid Butyl Sealer
HB Fuller E709-19554-B or equivalent meeting Ford Specification
ESB-M4G162-A:
Does not run.
Is fast drying.
Remains semi-elastic.
Can be used for seam sealing on the floorpan, wheelhouse, body
rocker panels, door ope ...
Gearshift Rail and Fork
Disassembly and Assembly
1. Using a 5/32-inch drift and a hammer, remove and discard the split pin.
Slide the shift fork from
the shift rail.
2. Remove the gearshift fork inserts.
3. CAUTION: Support the shift rail to prevent damage to the parts.
Positio ...