Ford Mustang (1999-2004) Service Manual: Fuel Charging and Controls - 4.6L (2V)

General Specifications

General Specifications

Torque Specifications

General Specifications

Supply Manifold
Removal and Installation WARNING: Do not smoke or carry lighted tobacco or open flame of any type when working on or near any fuel related components. Highly flammable mixtures are always present an ...

Fuel Charging And Controls
The fuel injection supply manifold (9F792): delivers fuel to the fuel injector. receives fuel from the fuel supply line. The throttle body (9E926): controls air supply to the upper intake manifo ...

Other materials:

Final assembly
23. Install the differential assembly in the differential housing. For additional information, refer to Differential Case in this section. 24. CAUTION: Align the index marks. CAUTION: Install the driveshaft with new bolts. If new bolts are not available, a ...

Degas Bottle - 4.6L(2V) and 4.6L(4V)
Removal and Installation 1. Drain the engine coolant from the degas bottle only. For additional information, refer to Cooling System Draining, Filling and Bleeding in this section. 2. Disconnect the radiator vent hose. 3. Remove the degas bottle return hos ...

Air Cleaner Outlet Pipe - 3.8L
Removal and Installation 1. Remove the air cleaner outlet tube. 1. Loosen the clamps. 2. Disconnect the hose. 3. Remove the tube. 2. To install, reverse the removal procedure. Air Cleaner Outlet Pipe -4.6L (2V) Removal and Installation 1. Dis ...