Ford Mustang (1999-2004) Service Manual: Pump - CIII
Special Tool(s)
|
|
Teflon Seal Replacer Set 211-D027 (D90P-3517-A) or equivalent |
Removal and Installation
1. Remove the pulley. For additional information, refer to Pulley-CIII Pump in this section.
2. Remove the bolt and bracket.

3. Disconnect the power steering hoses. Remove and discard the seal ring.

4. Remove bolts and the power steering pump (3A674).

5. To install, reverse the removal procedure.
- Using the special tool, install a new seal ring.


6. Fill and leak check the power steering system.
Pump - CII
Special Tool(s)
Teflon Seal Replacer Set
211D027 (D90P-3517-A) or
equivalent
Removal and Installation
1. Disconnect the power steering hose. Remove and discard the seal ring.
2. Di ...
Pulley - CII Pump
Special Tool(s)
Pump Pulley Installer
211-009 (T65P-3A733-C)
Pump Pulley Remover
211-016 (T69L-10300-B)
Removal
1. Remove the drive belt.
2. Using the special tool, remove ...
Other materials:
Transmission (Disassembly)
Special Tool(s)
Holding Fixture, Transmission
307-003 (T57L-500-B)
Puller, Bearing
205-D064 (D84L-1123-A)
2 or 3 Jaw Puller
205-D027 (D80L-1013-A)
Remover, Mainshaft Bearing
308-058 (T77J-7025-H)
...
Thermostat - 4.6L(4V)
Material
Item
Specification
Motorcraft Premium Gold
Engine Coolant
VC-7-A (in Oregon VC-7-B)
(yellow color)
WSS-M97B51-
A1
Removal and Installation
1. With the vehicle in neutral, position it on a hoist. For additional
information, ...
Exhaust Manifold to Exhaust Gas Recirculation (EGR)
Valve Tube
Removal and Installation
NOTE: 3.8L shown, 4.6L (2V) similar.
1. With the vehicle in NEUTRAL, position it on a hoist.
2. Disconnect the exhaust gas recirculation (EGR) valve tube from the
exhaust manifold.
3. Remove the differential feedback exhaust ga ...