Ford Mustang (1999-2004) Service Manual: Valve Cover RH
Material
| Item | Specification |
| Metal Surface Cleaner F4AZ-19A536-RA or equivalent | WSE-M5B392- A |
| Silicone Gasket and Sealant F7AZ-19554-EA or equivalent | WSE-M4G323- A4 |
| PAG Refrigerant Compressor Oil F7AZ-19589-DA (Motorcraft YN-12-C) or equivalent | WSH-M1C231- B |
Installation
1. Install the lower intake manifold gaskets.
2. Connect the fuel charging wiring harness to the rear of the lower intake
manifold and install the
manifold.
3. Install the intake manifold fastener ...
Removal
1. Disconnect the battery ground cable. For additional information, refer to
Section.
2. Drain the cooling system. For additional information, refer to Section.
3. Recover the refrigerant. For addi ...
Other materials:
Air Cleaner Element - 4.6L (2V)
Removal and Installation
1. Remove the air cleaner outlet tube (9B659). For additional
information, refer to Air Cleaner
Outlet Pipe-4.6L (2V) in this section.
2. Remove the mass air flow (MAF) assembly.
1. Release the clip.
2. Remove the MAF sens ...
Manual
WARNING: Brake fluid contains polyglycol ethers and polyglycols.
Avoid contact with
eyes. Wash hands thoroughly after handling. If brake fluid contacts
eyes, flush eyes with
running water for 15 minutes. Get medical attention if irritation
persist ...
Torque Converter Diagnosis
Prior to the installation of a new or remanufactured torque
converter, all diagnostic procedures must be
followed. This is to prevent the unnecessary installation of torque
converters. Only after a complete
diagnostic evaluation can the decision be m ...