Ford Mustang (1999-2004) Service Manual: Blower Motor
Removal
1. Disconnect the jumper wire.
2. Disconnect the main harness.
3. Remove the screws.
4. Separate the cover from the motor.
5. Separate the motor from the housing.
6. Disconnect the jumper from the motor.
- Remove the blower motor.
Installation
1. To install, reverse the removal procedure.
Heating and Defrosting
The heating and defrosting system has the following features: Controls the temperature and, during A/C operation, reduces the relative humidity of the air inside the vehicle. Delivers heated or ...Evaporator Core Housing
Material Item Specification PAG Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C) WSH-M1C231- B MERPOL NA ESE-M99B144- B Removal NOTE: The evapor ...Other materials:
Inspection and Verification
1. Verify the customer concern by operating the engine to duplicate the
condition.
2. Visually inspect for obvious signs of mechanical damage. Refer to the
following chart.
Visual Inspection Chart
Mechanical
Engine coolant leaks
...
Flywheel Ring Gear
Removal
1. Remove the flywheel.
2. WARNING: This procedure should be carried out only by a
correctly equipped and
experienced acetylene torch operator. Tongs must be used or asbestos gloves
worn
when handling the heated flywheel ring gear. Failure to f ...
Installation
1. CAUTION: Timing chain procedures must be followed exactly or damage
to the
pistons or valves will result.
Compress the tensioner plunger, using a soft-jawed vise.
2. Install a retaining clip on the tensioner to hold the plunger in during
installation.
...