Ford Mustang (1999-2004) Service Manual: Generator - 3.8L
Removal and Installation
1. Disconnect the battery (10655). For additional information, refer to Section.
2. Relieve the accessory drive belt (8620) tension and remove the belt from the generator pulley.
Leave the belt in place for reinstallation. For additional information, refer to Section.
3. CAUTION: This is a new style connector that has a press-to-release tab. Pulling on the tab could result in damage to the connector or harness.
Disconnect the generator (10300).
1. Disconnect the generator electrical connectors.
2. Remove the battery positive cable nut.
4. Remove the generator.
- Remove the upper and lower generator bolts.
5. To install, reverse the removal procedure.
Generator and Regulator
General Specifications Torque Specifications Generator The charging system consists of the: generator (GEN) internal voltage regulator The generator has an internal voltage regulato ...Generator - 4.6L 2V
Removal and Installation 1. Disconnect the battery (10655). For additional information, refer to Section. 2. Relieve the accessory drive belt (8620) tension and remove the belt from the gen ...Other materials:
Safety belt-minder
This feature supplements the safety belt warning function by providing
additional reminders by intermittently sounding a chime and illuminating
the safety belt warning light when the driver’s or front passenger’s seat is
occupied and the safety belt is unb ...
System Flushing - CIII Power Steering Pump
WARNING: Do not mix oil types. Any mixture or any unapproved oil can
lead to seal
deterioration and leaks. A leak can ultimately cause loss of fluid, which can
result in a loss of
power steering assist.
1. Remove the fuel pump fuse from the battery junction ...
Diagnostic Trouble Code Charts
Diagnostic Trouble Code Chart
Five
Digit
DTC
Component
Description
Condition
Symptom
Action
P0102
P0103
P1100
P1101
MAF
MAF concerns
MAF system has a
malfunction which
may cause a
transmission
concern.
High or low ...