Ford Mustang (1999-2004) Service Manual: Master Cylinder Priming - 4.6L

1. CAUTION: Use only bleed screws on the engine side of the brake master cylinder (2140). The hydro-boost bleed screw, located near the dash on the hydro-booster casting, is for the booster cavity filled with power steering fluid, not brake fluid.

Connect a clear waste line to the bleed screw closet to the booster first and the other end in a container partially filled with recommended brake fluid.

Bleeding - Components

2. Open the bleeder screw, have an assistant push the brake pedal down slowly through full travel, close the bleeder screw, then return brake pedal slowly to full released position. Wait five seconds, then repeat operation until air bubbles cease to appear.

3. Repeat Step 2 for bleeder screw farthest from hydro-booster.

Bleeding - Components

    Master Cylinder Priming - In-Vehicle or Bench
    WARNING: Brake fluid contains polyglycol ethers and polyglycols. Avoid contact with eyes. Wash hands thoroughly after handling. If brake fluid contacts eyes, flush eyes with running water for 15 min ...

    Four Wheel Anti-Lock Brake System (4WABS) Hydraulic Control Unit (HCU)
    NOTE: This procedure only needs to be performed if the 4-wheel anti-lock brake (4WABS) hydraulic control unit (HCU) has been installed new or if the HCU lines have been opened. 1. Clean all ...

    Other materials:

    Headliner
    Removal 1. Remove the two upper quarter panels. For additional information, refer to Trim Panel-Upper Quarter in this section. 2. Remove the two windshield side garnish mouldings. 3. Remove the two sun visors. 1. Remove the six screws. 2. ...

    Anti-Lock Control
    Refer to Wiring Diagrams Cell 42 , Anti-Lock Brake for schematic and connector information. Special Tool(s) Worldwide Diagnostic System (WDS) 418-F224, New Generation STAR (NGS) Tester 418-F052, or equivalent scan tool 73 Digita ...

    Fuel Injectors
    Material Item Specification SAE 5W-20 Premium Synthetic Blend Motor Oil XO-5W20-QSP or equivalent WSS-M2C153- H Removal and Installation WARNING: Do not smoke or carry lighted tobacco or open flame of any type when working on or near ...