Ford Mustang (1999-2004) Service Manual: Linkage Adjustment
System Bleeding
1. If required, remove the hydraulic system from the vehicle. Refer
to Hydraulic System, Lift
Cylinder and Motor in this section.
2. Remove the fill plug at the end of the hydraulic pump.
3. ...
Material
Item
Specification
Threadlock and
Sealer
E0AZ-19554-AA
WSK-M2G351-A5 (type
II)
Shoulder Bolt Kit
F5ZZ-76539A04-A
-
NOTE: Before starting the adjustment process, inspe ...
Other materials:
Removal
1. Disconnect the battery negative cable.
2. Drain the engine cooling system.
3. Remove the LH exhaust manifold. For additional information, refer to
Exhaust Manifold-LH in
this section.
4. Remove the lower intake manifold. For additional informatio ...
Transmission Draining and Filling
Material
Item
Specification
DEXRON III (ATF)
Transmission Fluid
XT-2-QDX
DEXRON III
1. Remove the drain plug and drain the transmission.
Position a suitable drain pan under the transmission.
2. Clean and install the drain plug.
3. N ...
Degas Bottle - 4.6L(2V) and 4.6L(4V)
Removal and Installation
1. Drain the engine coolant from the degas bottle only. For additional
information, refer to Cooling
System Draining, Filling and Bleeding in this section.
2. Disconnect the radiator vent hose.
3. Remove the degas bottle return hos ...