Ford Mustang (1999-2004) Service Manual: Linkage Adjustment
System Bleeding
1. If required, remove the hydraulic system from the vehicle. Refer
to Hydraulic System, Lift
Cylinder and Motor in this section.
2. Remove the fill plug at the end of the hydraulic pump.
3. ...
Material
Item
Specification
Threadlock and
Sealer
E0AZ-19554-AA
WSK-M2G351-A5 (type
II)
Shoulder Bolt Kit
F5ZZ-76539A04-A
-
NOTE: Before starting the adjustment process, inspe ...
Other materials:
Acceleration Control (Description and Operation)
Component Locations
The throttle is controlled by the accelerator cable which is connected to the
accelerator pedal and
shaft.
The accelerator pedal and shaft should travel smoothly from the idle to
the wide-open throttle
(WOT) positions. Hesi ...
Cable and Bracket
Removal
1. Raise the vehicle on a hoist. For additional information, refer to
Section.
2. Remove the cable shift from the shifter lever and bracket and discard
the clip.
3. Remove the bolt from the cable.
4. Remove the bolt from the cable.
5. ...
Mass Air Flow (MAF) Sensor - Cobra
Removal and Installation
1. Disconnect the intake air temperature (IAT) sensor.
2. Disconnect the breather hose.
3. Disconnect the vacuum hose.
4. Loosen the clamps and remove the air cleaner outlet pipe.
5. CAUTION: The mass air flow (MAF) sensor ho ...