Ford Mustang (1999-2004) Service Manual: Blower Motor
Removal
1. Disconnect the jumper wire.
2. Disconnect the main harness.
3. Remove the screws.
4. Separate the cover from the motor.
5. Separate the motor from the housing.
6. Disconnect the jumper from the motor.
- Remove the blower motor.
Installation
1. To install, reverse the removal procedure.
Heating and Defrosting
The heating and defrosting system has the following features:
Controls the temperature and, during A/C operation, reduces the relative
humidity of the air
inside the vehicle.
Delivers heated or ...
Evaporator Core Housing
Material
Item
Specification
PAG Compressor Oil (R-134a
Systems)
F7AZ-19589-DA (Motorcraft
YN-12-C)
WSH-M1C231-
B
MERPOL
NA
ESE-M99B144-
B
Removal
NOTE: The evapor ...
Other materials:
Output Shaft
Special Tool(s)
Puller, Bearing
205-D064 (D84L-1123-A)
Adapter for 303-224 (Handle)
205-153 (T80T-4000-W)
Installer, Output Shaft Rear
Bearing
308-401
Remover/Installer, Bearing
Tube
308-025 (T75L-7025 ...
Inspection and Verification
1. Verify the customer concern by operating the system.
2. Visually inspect for obvious signs of mechanical or electrical damage.
Visual Inspection Chart
Mechanical
Electrical
Power window
regulator
Window run
weatherstrip
Do ...
Component Test
Carry out the appropriate Functional Test(s) as determined in Inspection and
Verification.
Functional Test I (Buckle and Tongue)
The safety belt buckle and tongue assembly must operate freely during the
latching and unlatching
function. Fasten the safety bel ...