Ford Mustang (1999-2004) Service Manual: Linkage Adjustment

System Bleeding
1. If required, remove the hydraulic system from the vehicle. Refer to Hydraulic System, Lift Cylinder and Motor in this section. 2. Remove the fill plug at the end of the hydraulic pump. 3. ...

Material
Item Specification Threadlock and Sealer E0AZ-19554-AA WSK-M2G351-A5 (type II) Shoulder Bolt Kit F5ZZ-76539A04-A - NOTE: Before starting the adjustment process, inspe ...

Other materials:

Installation
1. CAUTION: Timing chain procedures must be followed exactly or damage to the pistons or valves will result. Compress the tensioner plunger, using a soft-jawed vise. 2. Install a retaining clip on the tensioner to hold the plunger in during installation. ...

Valve - Seat Inspection
Valve and Seat Refacing Measurements CAUTION: After grinding valves or valve seats, check valve clearance. 1. Check the valve head and seat. Check valve angles. Check margin width. Refer to the appropriate section in Group 303 for the procedure. ...

Extension Housing Seal and Gasket
Special Tool(s) Slide Hammer 100-001 (T50T-100-A) Installer, Transmission Extension Housing Fluid Seal 308-002 (T61L-7657-A) Remover, Transmission Fluid Seal 307-048 (T74P-77248-A) Removal 1. Drain the transmiss ...