Ford Mustang (1999-2004) Service Manual: Linkage Adjustment
System Bleeding
1. If required, remove the hydraulic system from the vehicle. Refer
to Hydraulic System, Lift
Cylinder and Motor in this section.
2. Remove the fill plug at the end of the hydraulic pump.
3. ...
Material
Item
Specification
Threadlock and
Sealer
E0AZ-19554-AA
WSK-M2G351-A5 (type
II)
Shoulder Bolt Kit
F5ZZ-76539A04-A
-
NOTE: Before starting the adjustment process, inspe ...
Other materials:
Installation
1. CAUTION: Timing chain procedures must be followed exactly or damage
to the
pistons or valves will result.
Compress the tensioner plunger, using a soft-jawed vise.
2. Install a retaining clip on the tensioner to hold the plunger in during
installation.
...
Valve - Seat Inspection
Valve and Seat Refacing Measurements
CAUTION: After grinding valves or valve seats, check valve
clearance.
1. Check the valve head and seat.
Check valve angles.
Check margin width.
Refer to the appropriate section in Group 303 for the procedure.
...
Extension Housing Seal and Gasket
Special Tool(s)
Slide Hammer
100-001 (T50T-100-A)
Installer, Transmission
Extension Housing Fluid Seal
308-002 (T61L-7657-A)
Remover, Transmission Fluid
Seal
307-048 (T74P-77248-A)
Removal
1. Drain the transmiss ...
