Ford Mustang (1999-2004) Service Manual: Linkage Adjustment
System Bleeding
1. If required, remove the hydraulic system from the vehicle. Refer
to Hydraulic System, Lift
Cylinder and Motor in this section.
2. Remove the fill plug at the end of the hydraulic pump.
3. ...
Material
Item
Specification
Threadlock and
Sealer
E0AZ-19554-AA
WSK-M2G351-A5 (type
II)
Shoulder Bolt Kit
F5ZZ-76539A04-A
-
NOTE: Before starting the adjustment process, inspe ...
Other materials:
Camshaft Journal - Clearance, Plastigage Method
Special Tool(s)
Plastigage
303-D031 (D81L-6002-B) or
equivalent
NOTE: The camshaft journals must meet specifications before checking
camshaft journal clearance.
1. Remove the camshaft bearing cap and lay Plastigage across the surface. Refer ...
Mass Air Flow (MAF) Sensor - 3.8L
Removal
CAUTION: The mass air flow (MAF) sensor hot wire sensing
element and housing are
calibrated as a unit and must be repaired as a complete assembly. Do not
damage the sensing
element (internal to housing) or possible failure to the mass air f ...
Output Shaft Speed (OSS) Sensor
Removal and Installation
1. With the vehicle in NEUTRAL, raise and support the vehicle.
2. Disconnect the electrical connector.
3. Remove the output shaft speed (OSS) sensor.
4. To install, reverse the removal procedure. ...