Ford Mustang (1999-2004) Service Manual: Linkage Adjustment

System Bleeding
1. If required, remove the hydraulic system from the vehicle. Refer to Hydraulic System, Lift Cylinder and Motor in this section. 2. Remove the fill plug at the end of the hydraulic pump. 3. ...

Material
Item Specification Threadlock and Sealer E0AZ-19554-AA WSK-M2G351-A5 (type II) Shoulder Bolt Kit F5ZZ-76539A04-A - NOTE: Before starting the adjustment process, inspe ...

Other materials:

Camshaft Journal - Clearance, Plastigage Method
Special Tool(s) Plastigage 303-D031 (D81L-6002-B) or equivalent NOTE: The camshaft journals must meet specifications before checking camshaft journal clearance. 1. Remove the camshaft bearing cap and lay Plastigage across the surface. Refer ...

Mass Air Flow (MAF) Sensor - 3.8L
Removal CAUTION: The mass air flow (MAF) sensor hot wire sensing element and housing are calibrated as a unit and must be repaired as a complete assembly. Do not damage the sensing element (internal to housing) or possible failure to the mass air f ...

Output Shaft Speed (OSS) Sensor
Removal and Installation 1. With the vehicle in NEUTRAL, raise and support the vehicle. 2. Disconnect the electrical connector. 3. Remove the output shaft speed (OSS) sensor. 4. To install, reverse the removal procedure. ...