Ford Mustang (1999-2004) Service Manual: Pump - CIII
Special Tool(s)
|
|
Teflon Seal Replacer Set 211-D027 (D90P-3517-A) or equivalent |
Removal and Installation
1. Remove the pulley. For additional information, refer to Pulley-CIII Pump in this section.
2. Remove the bolt and bracket.

3. Disconnect the power steering hoses. Remove and discard the seal ring.

4. Remove bolts and the power steering pump (3A674).

5. To install, reverse the removal procedure.
- Using the special tool, install a new seal ring.


6. Fill and leak check the power steering system.
Pump - CII
Special Tool(s)
Teflon Seal Replacer Set
211D027 (D90P-3517-A) or
equivalent
Removal and Installation
1. Disconnect the power steering hose. Remove and discard the seal ring.
2. Di ...
Pulley - CII Pump
Special Tool(s)
Pump Pulley Installer
211-009 (T65P-3A733-C)
Pump Pulley Remover
211-016 (T69L-10300-B)
Removal
1. Remove the drive belt.
2. Using the special tool, remove ...
Other materials:
Gearshift Lever and Boot
Material
Removal and Installation
1. Remove the gearshift lever knob.
2. Remove the console panel gearshift plate. Lift the gearshift lever boot
over the gearshift lever.
3. Remove the bolts and the shift lever.
4. Remove the screws and the inner shif ...
Transmission Fluid Cooler
CAUTION: Whenever a transmission has been disassembled to install
new parts, the
cooler bypass valve (CBV), all transmission fluid coolers (in tank and
auxiliary) and
transmission fluid cooler lines must be cleaned and backflushed. Use a
suitable the t ...
Keyless Entry/Computer Operated Locks
Programming -Keyless Entry Remote Transmitter
NOTE: All keyless entry remote transmitters (15K601) must be
programmed at the same time.
NOTE: All previous transmitter identification codes (TIC's) will be
erased when programming mode is
entered.
...