Ford Mustang (1999-2004) Service Manual: Dual-Function Pressure Switch (4.6L)

Dual-Function Pressure Switch (4.6L)

The dual-function pressure switch is used to interrupt A/C compressor operation in the event of high system discharge pressures.

  • The dual-function pressure switch is mounted on a Schrader valve-type fitting on the high pressure side of the A/C manifold and tube.
  • It is not necessary to discharge the refrigerant system to remove the dual-function pressure switch.
  • A valve depressor, located inside the threaded end of the dual-function pressure switch, presses on the Schrader valve stem.
  • This allows the dual-function pressure switch to monitor the compressor discharge pressure.
  • When the compressor discharge pressure rises, the switch contacts open, disengaging the A/C compressor. When the pressure drops, the contacts close to allow operation of the A/C compressor. For specifications regarding operating pressure(s), refer to Section.

The dual-function pressure switch has a second set of electrical contacts used for high-speed cooling fan control.

When the compressor discharge pressure rises, the contacts close and engage the high speed fan control. When the pressure drops, the contacts open and the high speed fan control is disengaged.

Refrigerant Containment Switch (3.8L)

The refrigerant containment switch is used to interrupt A/C compressor operation in the event of high system discharge pressures.

  • The refrigerant containment switch is mounted on a Schrader-type valve fitting on the high pressure side of the compressor manifold and tube assembly.
  • A valve depressor, located inside the threaded end of the refrigerant containment switch, presses on the Schrader valve stem.
  • This allows the refrigerant containment switch to monitor the A/C compressor discharge pressure.
  • When the A/C compressor discharge pressure rises, the switch contacts open, disengaging the A/C compressor. When the pressure drops, the contacts close to allow operation of the A/C compressor. For additional information regarding operating pressure(s), refer to Section.
  • It is not necessary to discharge the refrigerant system to remove the refrigerant containment switch.
    Suction Accumulator
      NOTE: Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of contamination from a failed A/C compres ...

    Spring Lock Coupling
      The spring lock coupling is a refrigerant line coupling held together by a garter spring inside a circular cage. When the coupling is connected together, the flared end of the female f ...

    Other materials:

    Pinpoint Tests
    PINPOINT TEST A: THE ENGINE DOES NOT CRANK AND THE RELAY DOES CLICK Test Step Result / Action to Take A1 CHECK THE VOLTAGE TO THE STARTER RELAY YesGO to A2 . No REPAIR circuit 1050 (LG/VT) for an open. TEST the system for normal operation. ...

    Battery (Diagnosis and Testing)
    Special Tool(s) Micro 490 Digital Battery Analyzer 162-00004 Inspection and Verification 1. Verify the customer concern by operating the system. 2. Visually inspect for obvious signs of mechanical or electrical damage. Visual Inspecti ...

    Trim Panel - Package Tray
    Special Tool(s) Torx Bit, Safety Belt Bolt 501-010 (T77L-2100-A) Removal and Installation 1. Remove the screw and the coat hook. 2. NOTE: Inspect the shoulder safety belt guide cover for damage. If the shoulder safety belt guide cover is d ...