Ford Mustang (1999-2004) Service Manual: Valve Cover LH

Material

Item Specification
Metal Surface Cleaner F4AZ-19A536-RA or equivalent WSE-M5B392-A
Silicone Gasket and Sealant F7AZ-19554-EA or equivalent WSE-M4G323- A4
Installation
1. NOTE: If the valve cover is not secured within four minutes, the sealant must be removed and the sealing area cleaned with metal surface cleaner. Allow to dry until there is no sign of wetness, o ...

Removal
All vehicles 1. Remove the air intake scoop. For additional information, refer to Section. 2. Remove the Hydro-Boost brake booster. For additional information, refer to Section.. 3. Raise and suppo ...

Other materials:

Torque Converter (Disassembly and Assembly of Subassemblies)
1. A new or remanufactured torque converter must be installed if one or more of the following statements is true: A torque converter malfunction has been determined based on complete diagnostic procedures. Converter stud or studs, impeller hub or bushin ...

Climate Control System (Description and Operation)
WARNING: To avoid accidental deployment and possible injury, the air bag system backup power supply must be depleted before repairing any climate control components. To deplete the backup power supply, disconnect the battery ground cable and wait one minute ...

Driveshaft (Removal and Installation)
Material Item Specification Threadlock and Sealer E0AZ-19554-AA WSK-M2G351-A5 (type II) Removal and Installation 1. Raise and support the vehicle. 2. Carry out the following: 1. Place an index mark on the rear axle pinion flange and ...