Ford Mustang (1999-2004) Service Manual: Valve Cover LH
Material
| Item | Specification |
| Metal Surface Cleaner F4AZ-19A536-RA or equivalent | WSE-M5B392-A |
| Silicone Gasket and Sealant F7AZ-19554-EA or equivalent | WSE-M4G323- A4 |
Installation
1. NOTE: If the valve cover is not secured within four minutes, the sealant
must be removed and
the sealing area cleaned with metal surface cleaner. Allow to dry until there is
no sign of
wetness, o ...
Removal
All vehicles
1. Remove the air intake scoop. For additional information, refer to Section.
2. Remove the Hydro-Boost brake booster. For additional information, refer to
Section..
3. Raise and suppo ...
Other materials:
Installation
1. Install the intake manifold and gaskets, tighten the bolts in the sequence
shown.
2. NOTE: The O-ring is to be installed on the top of the thermostat.
Install the water thermostat and the O-ring.
Install a new O-ring as necessary.
3. Install the wa ...
Synchronizers
Disassembly and Assembly
NOTE: This procedure applies to all synchronizer assemblies.
1. NOTE: Synchronizer components are not interchangeable. During
disassembly, mark each
individual synchronizer for assembly. Synchronizer hubs and sleeves are a
selected a ...
Engine Ignition (Description and Operation)
Eight separate ignition coils (12029):
are mounted directly above each spark plug (12405).
are controlled by the powertrain control module (PCM) for correct
firing sequence.
The spark plug:
changes the high voltage pulse into a spark which igni ...