Ford Mustang (1999-2004) Service Manual: Valve Cover RH
Removal and Installation
1. Remove the throttle body. For additional information, refer to Section.
2. Disconnect the crankcase vent hose.

3. Remove the differential feedback exhaust gas recirculation (EGR) system vacuum hoses and the bracket bolts. Position the bracket assembly aside.

4. Disconnect the EGR tube.

5. Remove the EGR tube.

6. Position the spark plug wires aside.

7. Remove the RH valve cover.

8. To install, reverse the removal procedure.
- Install a new valve cover gasket as necessary.
Valve Cover - LH
Removal and Installation
1. Position the ignition wires (12281) aside.
2. Disconnect the positive crankcase ventilation (PCV) valve (6758).
3. Remove the ignition coil and position aside.
1. ...
Crankshaft Pulley
Special Tool(s)
Remover, Crankshaft Vibration
Damper
303-009 (T58P-6316-D)
Remover, Crankshaft Vibration
Damper
303-176 (T82L-6316-B)
Installer, Crankshaft
Damper/C ...
Other materials:
Under hood overview
3.7L V6 Engine
A. Battery
B. Engine oil dipstick
C. Engine oil filler cap
D. Brake fluid reservoir
E. Air filter assembly
F. Engine coolant reservoir
G. Windshield washer fluid reservoir
H. Power distribution box
5.0L V8 Engine
A. Battery
B. Engine oil fille ...
Pinpoint Tests
CAUTION: Before removing and installing the GEM or its connectors,
disconnect the battery. Failure to follow this caution will
result in the GEM storing many erroneous DTCs and
may result in the GEM exhibiting erratic operation after installation.
CAUTI ...
Running out of fuel
Avoid running out of fuel because this situation may have an adverse
effect on powertrain components.
If you have run out of fuel:
• You may need to cycle the ignition from off to on several times after
refueling to allow the fuel system to pump the fuel fr ...