Ford Mustang (1999-2004) Service Manual: Valve Cover RH

Removal and Installation

1. Remove the throttle body. For additional information, refer to Section.

2. Disconnect the crankcase vent hose.

Valve Cover RH

3. Remove the differential feedback exhaust gas recirculation (EGR) system vacuum hoses and the bracket bolts. Position the bracket assembly aside.

Valve Cover RH

4. Disconnect the EGR tube.

Valve Cover RH

5. Remove the EGR tube.

Valve Cover RH

6. Position the spark plug wires aside.

Valve Cover RH

7. Remove the RH valve cover.

Valve Cover RH

8. To install, reverse the removal procedure.

  • Install a new valve cover gasket as necessary.
    Valve Cover - LH
    Removal and Installation 1. Position the ignition wires (12281) aside. 2. Disconnect the positive crankcase ventilation (PCV) valve (6758). 3. Remove the ignition coil and position aside. 1. ...

    Crankshaft Pulley
    Special Tool(s) Remover, Crankshaft Vibration Damper 303-009 (T58P-6316-D) Remover, Crankshaft Vibration Damper 303-176 (T82L-6316-B) Installer, Crankshaft Damper/C ...

    Other materials:

    Removal
    1. Remove the A/C compressor (19703). For additional information, refer to Air Conditioning (A/C) Compressor-3.8L or Air Conditioning (A/C) Compressor-4.6L in this section. 2. Remove the bolt. 1. Hold the A/C disc and hub assembly (19D786) with the special ...

    Installation
    1. CAUTION: Timing chain procedures must be followed exactly or damage to the pistons or valves will result. Compress the tensioner plunger, using a soft-jawed vise. 2. Install a retaining clip on the tensioner to hold the plunger in during installation. ...

    Output Shaft Speed (OSS) Sensor
    Removal and Installation 1. With the vehicle in NEUTRAL, raise and support the vehicle. 2. Disconnect the electrical connector. 3. Remove the output shaft speed (OSS) sensor. 4. To install, reverse the removal procedure. ...