Ford Mustang (1999-2004) Service Manual: Valve Cover LH

Material

Item Specification
Metal Surface Cleaner F4AZ-19A536-RA or equivalent WSE-M5B392-A
Silicone Gasket and Sealant F7AZ-19554-EA or equivalent WSE-M4G323- A4
Installation
1. NOTE: If the valve cover is not secured within four minutes, the sealant must be removed and the sealing area cleaned with metal surface cleaner. Allow to dry until there is no sign of wetness, o ...

Removal
All vehicles 1. Remove the air intake scoop. For additional information, refer to Section. 2. Remove the Hydro-Boost brake booster. For additional information, refer to Section.. 3. Raise and suppo ...

Other materials:

Exhaust Manifold LH
Removal and Installation 1. Position the steering wheel straight ahead and lock the column. 2. Disconnect the battery ground cable. For additional information, refer to Section. 3. Raise the vehicle. For additional information, refer to Section. 4. Remove ...

Air Cleaner - 3.8L
Removal and Installation 1. Remove the air cleaner outlet tube from the throttle body. For additional information, refer to Air Cleaner Outlet Pipe-3.8L in this section. 2. Disconnect the connector. 3. Remove the bolt. 4. Remove the air cleaner and d ...

Engine coolant check
Checking the Engine Coolant The concentration and level of engine coolant should be checked at the intervals listed in Scheduled Maintenance Information. Note: Make sure that the level is at the FULL COLD level or within the COLD FILL RANGE in the coolant res ...