Ford Mustang (1999-2004) Service Manual: Valve Cover LH
Material
| Item | Specification |
| Metal Surface Cleaner F4AZ-19A536-RA or equivalent | WSE-M5B392-A |
| Silicone Gasket and Sealant F7AZ-19554-EA or equivalent | WSE-M4G323- A4 |
Installation
1. NOTE: If the valve cover is not secured within four minutes, the sealant
must be removed and
the sealing area cleaned with metal surface cleaner. Allow to dry until there is
no sign of
wetness, o ...
Removal
All vehicles
1. Remove the air intake scoop. For additional information, refer to Section.
2. Remove the Hydro-Boost brake booster. For additional information, refer to
Section..
3. Raise and suppo ...
Other materials:
Module - Daytime Running Lamps (DRL)
Removal
1. CAUTION: Electronic modules are sensitive to static electrical
charges. If exposed
to these charges, damage can result.
Disconnect the battery ground cable.
2. Remove the daytime running lamps (DRL) module and bracket assembly
(15A270).
...
Refrigerant System Tests
Special Tool(s)
R-134a Manifold Gauge Set
176-R032A or equivalent
1. Connect the R-134a Manifold Gauge Set. For additional information, refer
to Manifold Gauge
Set Connection in this section.
2. Adjust the climate controls for maximum cooling ...
Inspection and Verification
NOTE: A new instrument cluster must be reconfigured.
NOTE: The instrument panel dimmer switch is a part of the headlamp
switch.
1. Verify the customer concern.
2. Visually inspect for obvious signs of electrical damage.
Visual Inspection Chart
Electric ...