Ford Mustang (1999-2004) Service Manual: Spring Lock Coupling
Special Tool(s)
![]() |
Remover, Refrigerant Coupling Set 412-039 (T84L-19623-B) |
Air Conditioning (A/C) System Check - Retail Procedure
NOTE: This Retail Procedure is not eligible for claiming on Ford
paid repairs (warranty and ESP).
NOTE: The engine should be run at idle for 10 minutes with the air
conditioning on and set to MA ...
Disconnect
1. Remove the A/C tube lock coupling clip (19E746), if equipped.
2. Fit the special tool to the spring lock coupling.
3. Push the tool into the cage opening to release the female fitting from the ...
Other materials:
Mass Air Flow (MAF) Sensor - 4.6L (2V)
Removal
CAUTION: The mass air flow (MAF) sensor hot wire sensing
element and housing are
calibrated as a unit and must be repaired as a complete assembly. Do not
damage the sensing
element (internal to housing) or possible failure to the mass air f ...
Disassembly
1. Remove the differential assembly from the differential housing. For
additional information, refer
to Differential Case in this section.
2. Remove the 10 bolts.
3. CAUTION: Do not damage the threads in the bolt holes.
Insert a punch in the bolt holes, a ...
2-3 Accumulator
Removal
1. Remove the main control valve body. For additional information, refer to
Main Control Valve
Body in this section.
2. Remove the 2-3 accumulator piston retainer.
3. Remove the accumulator piston and spring.
Installation