Ford Mustang (1999-2004) Service Manual: Spring Lock Coupling
Special Tool(s)
![]() |
Remover, Refrigerant Coupling Set 412-039 (T84L-19623-B) |
Air Conditioning (A/C) System Check - Retail Procedure
NOTE: This Retail Procedure is not eligible for claiming on Ford
paid repairs (warranty and ESP).
NOTE: The engine should be run at idle for 10 minutes with the air
conditioning on and set to MA ...
Disconnect
1. Remove the A/C tube lock coupling clip (19E746), if equipped.
2. Fit the special tool to the spring lock coupling.
3. Push the tool into the cage opening to release the female fitting from the ...
Other materials:
Using the boot
Installing the Boot
WARNING: Always secure the retaining clips and boot straps on
the vehicle or the boot may come loose while driving.
Note: Be sure the boot is secure on the vehicle before driving.
Improper
installation can result in loss or damage of the b ...
Supercharger Cooling System Draining, Filling and
Bleeding
Draining
WARNING: Never remove the pressure relief cap while the engine is
operating or when the
cooling system is hot. Failure to follow these instructions can result in damage
to the cooling
system or engine or personal injury. To avoid having scalding hot ...
Connecting Rod - Bushing Diameter
1. Measure the inner diameter of the connecting rod bushing, if equipped.
Verify the diameter is
within specification.
Refer to the appropriate section in Group for the procedure.
If out of specification, install new components as necessary. Refer
...