Ford Mustang (1999-2004) Service Manual: Spring Lock Coupling

Special Tool(s)

Remover, Refrigerant Coupling Set 412-039 (T84L-19623-B)
Air Conditioning (A/C) System Check - Retail Procedure
NOTE: This Retail Procedure is not eligible for claiming on Ford paid repairs (warranty and ESP). NOTE: The engine should be run at idle for 10 minutes with the air conditioning on and set to MA ...

Disconnect
1. Remove the A/C tube lock coupling clip (19E746), if equipped. 2. Fit the special tool to the spring lock coupling. 3. Push the tool into the cage opening to release the female fitting from the ...

Other materials:

Evaporative Emission Test Port
Removal and Installation 1. Disconnect the pin-type retainer. 2. Raise and support the vehicle. For additional information, refer to Section. 3. Remove the RH front wheel. For additional information, refer to Section. 4. Remove the RH front splash shiel ...

Transmission (Removal)
1. Disconnect the battery ground cable. For additional information, refer to Section. 2. Lift up on the clutch pedal and secure it in place. 3. Remove the gearshift lever knob (7213). 4. Remove the console panel gearshift plate. Lift the gearshift leve ...

Drive Pinion Flange and Drive Pinion Seal
Special Tool(s) 2-Jaw Puller 205-D072 (D97L-4221-A) or equivalent Holding Fixture, Drive Pinion Flange 205-126 (T78P-4851-A) Installer, Drive Pinion Flange 205-002 (TOOL-4858-E) or equivalent ...