Ford Mustang (1999-2004) Service Manual: Valve Cover RH

Material

Item Specification
Metal Surface Cleaner F4AZ-19A536-RA or equivalent WSE-M5B392- A
Silicone Gasket and Sealant F7AZ-19554-EA or equivalent WSE-M4G323- A4
PAG Refrigerant Compressor Oil F7AZ-19589-DA (Motorcraft YN-12-C) or equivalent WSH-M1C231- B
Installation
1. Install the lower intake manifold gaskets. 2. Connect the fuel charging wiring harness to the rear of the lower intake manifold and install the manifold. 3. Install the intake manifold fastener ...

Removal
1. Disconnect the battery ground cable. For additional information, refer to Section. 2. Drain the cooling system. For additional information, refer to Section. 3. Recover the refrigerant. For addi ...

Other materials:

Electronic Vibration Analyzer (EVA)
The EVA is a hand-held electronic diagnostic tool which will assist in locating the source of unacceptable vibrations. The vibration sensor can be remotely mounted anywhere in the vehicle for testing purposes. The unit displays the three most common vibratio ...

Component Tests
Engine Oil Leaks NOTE: When diagnosing engine oil leaks, the source and location of the leak must be positively identified prior to repair. Prior to carrying out this procedure, clean all sealing surface areas with a suitable solvent to remove all tra ...

Installation
All vehicles 1. NOTE: If the valve cover is not secured within four minutes, the sealant must be removed and the sealing area cleaned with metal surface cleaner. Allow to dry until there is no sign of wetness, or four minutes, whichever is longer. Failure to ...