Ford Mustang (1999-2004) Service Manual: Fuel Charging and Controls - 3.8L
General Specifications

Torque Specifications

Degas Bottle
Removal and Installation
1. Drain the coolant. For additional information, refer to Supercharger
Cooling System Draining,
Filling and Bleeding in this section.
2. Disconnect the coolant hoses.
...
Other materials:
Canister Vent Solenoid Closing Procedure
Special Tool(s)
Worldwide Diagnostic System
(WDS)
418-F224,
New Generation STAR (NGS)
Tester
418-F052, or equivalent scan
tool
CAUTION: The canister vent solenoid must not be energized for more than
nine minutes
at one time. Once the ...
Extension Housing Seal and Gasket
Special Tool(s)
Slide Hammer
100-001 (T50T-100-A)
Installer, Transmission
Extension Housing Fluid Seal
308-002 (T61L-7657-A)
Remover, Transmission Fluid
Seal
307-048 (T74P-77248-A)
Removal
1. Drain the transmiss ...
Output Shaft Speed (OSS) Sensor
Removal and Installation
1. With the vehicle in NEUTRAL, raise and support the vehicle.
2. Disconnect the electrical connector.
3. Remove the output shaft speed (OSS) sensor.